357 research outputs found

    Case formulation—A vehicle for change? Exploring the impact of cognitive behavioural therapy formulation in first episode psychosis: A reflexive thematic analysis

    Get PDF
    Objectives: Formulation is considered a fundamental process of cognitive behavioural therapy for psychosis (CBTp). However, an exploration into the personal impact of different levels of case formulation (CF) from a service user perspective (SU) is lacking, particularly for those experiencing a first episode of psychosis. Design: This Big Q qualitative design used semi-structured interviews. Methods: Reflexive thematic analysis (TA) was used to analyse 10 participant interviews. NVivo 12 computer-assisted qualitative data analysis software aided data organisation and analysis. Results: One overarching theme ‘CF – A vehicle for change?’ was developed as a pattern of shared meaning across the data set. Three main themes related to the overarching theme: (1) Vicious cycles: ‘I never really thought about it being me maintaining the problems’ (including one subtheme – Self-empowerment: ‘Only you can make the changes for yourself’); (2) Early life experiences: ‘My experiences have shaped the person that I am, therefore, it's not my fault’ (including one subtheme – Disempowerment: ‘[My] core beliefs have been damaged’); and (3) Keep it simple: ‘Don't push it too far over the top in case it becomes like spaghetti’. Conclusions: Maintenance formulations may be experienced as self-blaming, but also self-empowering, which may help to facilitate change. Longitudinal formulations may be experienced as non-blaming, but also disempowering, which may inhibit change. Simple CF diagrams may also facilitate change, whereas overly complex CFs may inhibit change. How CBTp therapists might look to improve the impact of different levels of CF for service users (SUs) in first episode psychosis (FEP) are described

    Relations among restricted and repetitive behaviors, anxiety and sensory features in children with autism spectrum disorders

    Get PDF
    The purpose of this study was to explore how atypical reactions to sensory stimuli contribute to the relation between restricted and repetitive behaviors and anxiety in children with autism spectrum disorders (ASD). In Study 1, factor analysis of restricted and repetitive behaviors was carried out using the Repetitive Behavior Questionnaire-2 (RBQ-2), completed by 120 parents of 2- to 17-year-olds with ASD. Two subtypes resulted: repetitive sensory and motor behaviors, and insistence on sameness, accounting for 40% of the variance. This two-factor solution was retained even when the sensory items of the RBQ-2 were removed. In Study 2, 49 of the same parents also completed the Spence Anxiety Scales and the Sensory Profile. The insistence on sameness factor was significantly associated with anxiety while the repetitive motor behaviors factor was not. The relation between anxiety and insistence on sameness was mediated by sensory avoiding and to a lesser extent by sensory sensitivity. Implications for arousal explanations of ASD and for clinical practice are discussed

    Ultrasound Evaluation of Fluid in Knee Recesses at Varying Degrees of Flexion

    Get PDF
    Various methods are utilized in daily practice to obtain optimal information on effusion in the knee. Our aim is to investigate which scanning position provides the best information about synovial fluid in the knee by using ultrasound and to evaluate the magnitude of difference for measuring synovial fluid in 3 major recesses (suprapatellar, medial parapatellar, and lateral parapatellar) of the knee according to various degrees of flexion. Sonographers in 14 European centers documented bilateral knee joint ultrasound examinations on a total of 148 knee joints. The largest sagittal diameter of fluid was measured in scans corresponding to the 3 major recesses at different (0\ub0, 15\ub0, 30\ub0, 45\ub0, 60\ub0, and 90\ub0) degrees of flexion of the knee. The difference of measurement of effusion according to transducer position, knee position, and the interaction between them was investigated by analysis of variance followed by Tukey's test. No correlation was noted between patient characteristics and ultrasound detection of effusion. The sagittal diameter of synovial fluid in all 3 recesses was greatest at 30\ub0 flexion. Analysis of variance and Tukey's test revealed that the suprapatellar scan and 30\ub0 flexion is the best combination for detecting effusion as confirmed by receiver operator characteristic curve analysis. The suprapatellar scan of the knee in 30\ub0 flexion was the most sensitive position to detect fluid in knee joints. Sagittal diameter of fluid in all 3 recesses increased with the knee in the 30\ub0 flexed position as compared to the extended position. Copyright \ua9 2012 by the American College of Rheumatology

    Ultrasound in the evaluation of enthesitis: status and perspectives

    Get PDF
    Introduction: An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter. Methods: Search was performed in PUBMED and EMBASE. Both grey-scale and Doppler definitions of enthesitis, including describing features of enthesitis, were collected and metrological qualities of studies were assessed. Results: After selection, 48 articles were analyzed. The definition of ultrasound enthesitis and elementary features varied among authors. Grey-scale enthesitis was characterized by increasing thickness (94% of studies), hypoechogenicity (83%), enthesophytes (69%), erosions (67%), calcifications (52%), associated bursitis (46%) and cortical irregularities (29%). Only 46% of studies reported the use of Doppler. High discrepancies were observed on frequency, type of probe and Doppler mode used. Face and content validity were the most frequently evaluated criteria (43%) followed by reliability (29%) and responsiveness (19%). Conclusions: Ultrasound has evidence to support face, content validity and reliability for the evaluation of enthesitis, though there is a lack of well-reported methodology in most of the studies. Consensus on elementary lesions and standardization of exam is needed to determine the ultrasound definition of enthesitis in grey-scale and in Doppler for future applications.15 page(s

    A Systematic Literature Review Analysis of Ultrasound Joint Count and Scoring Systems to Assess Synovitis in Rheumatoid Arthritis According to the OMERACT Filter

    Get PDF
    Objective. The OMERACT Ultrasound Task Force is currently developing a global synovitis score (GLOSS) with the objective of feasibly measuring global disease activity in patients with rheumatoid arthritis (RA). In order to determine the minimal number of joints to be included in such a scoring system, and to analyze the metric properties of proposed global (i.e., patient level) ultrasound (US) scoring systems of synovitis in RA, a systematic analysis of the literature was performed. Methods. A systematic literature search of Pubmecl and Embase was performed (January 1, 1984, to March 31, 2010). Original research reports written in English including RA, ultrasound, Doppler, and scoring systems were included. The design, subjects, methods, imaging protocols, and performance characteristics studied were analyzed, as well as the ultrasound definition of synovitis. Results. Of 3004 reports identified, 14 articles were included in the review. We found a lack of clear definition of synovitis as well as varying validity data with respect to the proposed scores. Scoring systems included a wide range and number of joints. All analyzed studies assessed construct validity and responsiveness by using clinical examination, laboratory findings, and other imaging modalities as comparators. Both construct validity and responsiveness varied according to the number and size of joints examined and according to the component of synovitis measured [i.e., gray-scale (GS) or power Doppler (PD) alone or in combination]. With regard to feasibility, time of evaluation varied from 15 to 60 min and increased with the number of joints involved in the examination. Conclusions. Ultrasound can be regarded as a valuable tool for globally examining the extent of synovitis in RA. However, it is presently difficult to determine a minimal number of joints to be included in a global ultrasound score. Further validation of proposed scores is needed. (J Rheumatol 2011; 38:2055-62; doi:10.3899/jrheum.110424
    • 

    corecore